XXXXX Kubota, GL11000 Specifications">

GENERATORJOE

This is a new pop-up window on top of your browser window.

CLICK TO CLOSE WINDOW

 
Kubota Logo
GL11000
 
GL Logo Sign
Lowboy Sign
The new LOWBOY II Series generators are powered by vertical rather than horizontal diesel engines used in the previous LOWBOY Series. The new series matched the compact size, low body design, and low noise levels of its predecessor, while the SUPER MINI diesel engines enhance its environment friendly features.
 
 MODEL Unit GL11000
 Type - Rotating field single-phase AC generator
 Frequency Hz 60
 Standby Output kVA (kW) 11.0 (11.0)
 Prime Output kVA (kW) 10.0 (10.0)
 Voltage - Single Phase V 120/240
 Armature Connection - Series
 Phase / Wire - 1/3
 Power Factor - 1.0
 No. of Poles - 2
 Insulation Class Rotor coil; class F, Stator coil; class B
 Type of Coupling - Direct coupled
 AMPS
 Single Phase 120V A 83.3
 Single Phase 240V A 41.7
 NO. OF RECEPTACLE
 5-15R (GFCI) - N/A
 5-20RA (GFCI) - 2
 6-15R - N/A
 L5-30R - 1
 L6-30R - 1
 CS-6369 - 1
 TERMINAL
 Terminal - Available
 DIESEL ENGINE
 Type - Vertical, liquid-cooled,
4-cycle diesel engine
 Model - D722-EBG
 No. of Cylinders - 3
 Bore x Stroke mm (in.) 67.0 x 68.0 (2.6 x 2.7)
 Displacement L (cu. in.) 0.719 (43.9)
 Engine Speed rpm 3600
 Continuous Rated Output kW (HP) 12.2 (16.3)
 Lubricant
 (API classification)
- above CD grade
 Oil Capacity L (qts.) 3.4 (0.9)
 Coolant Capacity L (qts.) 4.1 (1.1)
 Starting System - Electric - 12 volt DC
 SET
 Fuel - Diesel fuel No.2
(ASTM D975)
 Fuel
 Consumption
at Full Load L/h (gal./h) 4.1 (1.09)
at 3/4 Load L/h (gal./h) 3.3 (0.86)
at 1/2 Load L/h (gal./h) 2.7 (0.71)
at 1/4 Load L/h (gal./h) 2.2 (0.59)
 Fuel Tank Capacity L (gal.) 28.0 (7.4)
 Continuous
 Operation
 Hours
at Full Load h 7.0
at 3/4 Load h 8.5
at 1/2 Load h 10.4
at 1/4 Load h 12.7
 Battery (Ah/5h) - 55B24R (12V x 36Ah)
 Dimensions
 L x W x H
mm
(in.)
1281 x 618 x 698
(50.4 x 24.3 x 27.5)
 Approx. Net Weight kg (lbs.) 295 (650)
 Sound Level
 (Full Load at 23 ft. [7m])
dB (A) 68
 Emergency Stop System - In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened (terminal type only)
 Copyright © 1999-2014 GeneratorJoe Inc. & GeneratorJoe®. All Rights Reserved.